Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair

Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair

Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair
Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair

صورة كبيرة :  Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair افضل سعر

تفاصيل المنتج:
اسم العلامة التجارية: JDP
Model Number: SPL-T
شروط الدفع والشحن:
Minimum Order Quantity: 1
Packaging Details: Standard Package
Payment Terms: T/T, Western Union
مفصلة وصف المنتج
Brand: Olympus Model: SPL-T
Ultrasonic crystal: Damaged Fault: No ultrasonic energy output
Solution: Replace the ultrasonic crystal

Olympus ShockPULSE-SE lithotripsy handpiece SPL-T for repair

 

 

Brief Description

 

 

Fault:

 

1.No ultrasonic energy output.

 

Ultrasonic crystal is damaged.

 

Solution: Replace the ultrasonic crystal.

 

 

 

Problem & Solutoin

 

Brand Olympus
Model SPL-T
Ultrasonic crystal Damaged
Fault No ultrasonic energy output
Solution Replace the ultrasonic crystal

 

 

 

Applications

 

The Olympus ShockPULSE-SE lithotripsy handpiece (SPL-T) is a key component of the Olympus ShockPULSE-SE Lithotripsy System, designed for efficient stone fragmentation and aspiration during various urological procedures like PCNL, URS, and bladder stone management.The Olympus ShockPULSE-SE system, with its SPL-T handpiece, represents an advanced solution for stone management, aiming for speed, efficiency, and intuitive surgeon control.

Common issues & Potential causes

 

 

  • Cable damage: The cable connecting the transducer to the generator can be damaged internally, interrupting power delivery.

  • Generator Issues: While the SPL-T is the handpiece, its function depends on the ShockPULSE-SE generator (SPL-G). Problems with the generator's power output or settings can directly impact the handpiece's performance.

  • Insufficient contact with the stone: The probe needs to be in light, direct contact with the stone.

  • Excessive pressure: Pressing down too hard on the stone can actually reduce drilling performance.

  • Incorrect power setting: Ensure the appropriate power setting (Standard "S" or High "H") is selected for the stone size and type.

 

If your instrument has any of the above problems or others, please feel free to contact us for assistance. We will do our best to help you solve the issue.

 

 

About Us

 

JDP is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

 

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

تفاصيل الاتصال
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED

اتصل شخص: Mr. Maud

الهاتف :: 13922729804

إرسال استفسارك مباشرة لنا